Fallen Bottle Detection and Ejection - a unit that can be used
up or down stream of a leak detector. Mainly used downstream to
stop fallen bottles clogging the entry to labellers and
printers.
This is a separate unit that can be bolted onto an existing
conveyor.
It has two photo sensors to check if a bottle has fallen.
Once detected the bottle is ejcted from the conveyor by a pneumatic
cyclinder.
The time the ejection cylinder is extended and the period from
detection to actuation is adjustable via the menu system.
The fallen bottle system is supplied with a 6m ( or longer) cable
that plugs into the leak detector cabinet for air and electrical
control.
|
|
|