A SIMPLE LOW COST WAY OF COUNTING BOTTLES AND WARNING THE
OPERATOR THAT THE BOX NEEDS TO BE CHANGED OVER, THIS CAN ALSO BE
AUTOMATED WITH THE OPTIONAL BOX DIVERTER.
The batch counter is enabled from our menu system.
A box count is set between 0 and 9999.
A box pre-warn count is set between 0 and 999. This turns on an
alarm (with adjustable volume & tone) to tell the operator the
box is almost full.
The alarm comes when the box count reaches the total box count
minus the pre-warn amount.
When the last good bottle is tested the alarm tone changes and a
Yellow LED is turn on momentarily indicating this is the last
bottle.

BOX DIVERTER
The basic batch count is required except that the bottle is now
counted by a photocell placed at the end of the conveyor.
At the batch count, a pneumatic cylinder moves a flap mounted off
the end of the conveyor over so that the next bottle goes into the
next box.
This arrangement is used for accumulation into 2 boxes.
Bottles could also be diverted into boxes on an indexing conveyor,
or in a pneumatic indexing rectangle.
We are prepared to look at these options.
COLLATION TABLES
The output from a leak detector can be collated in rows on a
collation table with an infeed conveyor and row push off cylinder.
This can be controlled from the leak detector processor or if
desired a separate mini-plc.
|
|
|